Forced circulation systems - pressurized

CPC 6 OEM / INOX / XL INOX

Evacuated tube collector with CPC-reflector - 6 evacuated tubes for water, space and process heating, series connection

Scope of Delivery: Fully pre-assembled unit comprising of:

  • Evacuated tubes based on the thermos flask principle
  • Manifold with direct flow heat conduction unit and dry tube connection
  • CPC-reflector

Collectors are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.

Installation Types:

  • On-roof Installation 
  • Flat roof / Wall Installation
  • Ground Installation

Note: The manifold must always be mounted on top. The minimum angle for on-roof and flat roof installation is 15°

Specification

Series   CPC 6 OEM CPC 6 INOX CPC 6 XL INOX
Internal piping   copper stainless steel stainless steel
Color (aluminum frame profile)   aluminum grey slate grey slate grey
Surface coating (aluminum frame profile)   anodized powder coated powder coated
No. of Evacuated Tubes   6 6 6
η (based on gross area), according to SRCC % 55.4 55.4 57.8
a1 (based on gross area), according to SRCC BTU/hr.ft².°F 0.14300 0.14300 0.14580
a2 (based on gross area), according to SRCC BTU/hr.ft².°F² 0.00030 0.00030 0.00036
Thermal Performance Rating (Category C; Clear Day) BTU per panel per day 12,100 12,100 15,100
Grid dimensions (length x width x depth) in 64.5 x 28 x 4 64.5 x 28 x 4 81 x 28 x 4
Gross surface area ft² 12.38 12.38 14.42
Aperture area ft² 10.76 10.76 13.15
Collector contents gal 0.24 0.24 0.3
Weight lbs 42 42 48
Max. working overpressure psi 150 150 150
Max. stagnation temperature °F 522 522 522
Connection diameter, compression ring mm 15 15 15
Sensor sleeve mm 6 6 6
Glass tube (Ø ext./Ø int./wall thckn./tube lgth.) in 1 7/8 / 1 1/2 / 1/16 / 59 1 7/8 / 1 1/2 / 1/16 / 59 1 7/8 / 1 1/2 / 1/16 / 76
Collector material   AI / Cu / glass / silicone / PBT / EPDM / TE AI / Cu / glass / silicone / PBT / EPDM / TE AI / Cu / glass / silicone / PBT / EPDM / TE
Glass tube material   borosilicate glass 3.3 borosilicate glass 3.3 borosilicate glass 3.3
Selective absorber coating material   aluminum nitride aluminum nitride aluminum nitride
Color (plastic parts)   black black black
Thermal shock test ITW test 06COL513/1 06COL513/1 06COL513/1
Hailstone test according to DIN EN 12975-2 TÜV test 435/142448 435/142448 435/142448
EC type examination   Z-IS-DDK-MUC-07-08-100029919-001 / -003 Z-IS-DDK-MUC-07-08-100029919-001 / -003 Z-IS-DDK-MUC-07-08-100029919-001 / -003
DIN CERTCO registration number   011-7S113R 011-7S113R 011-7S113R
SRCC OG-100 Certification number   2008008E 2008008E 2008008E
High Velocity Wind Certification   pending pending pending
Other tests and approvals   EN 12975, RAL ZU 73, Solar Keymark, ISO 9001 EN 12975, RAL ZU 73, Solar Keymark, ISO 9001 EN 12975, RAL ZU 73, Solar Keymark, ISO 9001

CPC 12 OEM / INOX / XL INOX

Evacuated tube collector with CPC-reflector - 12 evacuated tubes
for water, space and process heating, series connection

Scope of Delivery: Fully pre-assembled unit comprising of:

  • Evacuated tubes based on the thermos flask principle
  • Manifold with direct flow heat conduction unit and dry tube connection
  • CPC-reflector

Collectors are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.

Installation Types:

  • On-roof Installation 
  • Flat roof / Wall Installation
  • Ground Installation

Note: The manifold must always be mounted on top. The minimum angle for on-roof and flat roof installation is 15°

 

Specification

Series   CPC 12 OEM CPC 12 INOX CPC 12 XL INOX
Internal piping   copper stainless steel stainless steel
Color (aluminum frame profile)   aluminum grey slate grey slate grey
Surface coating (aluminum frame profile)   anodized powder coated powder coated
No. of Evacuated Tubes   12 12 12
η (based on gross area), according to SRCC % 55.4 55.4 57.8
a1 (based on gross area), according to SRCC BTU/hr.ft².°F 0.14300 0.14300 0,14580
a2 (based on gross area), according to SRCC BTU/hr.ft².°F² 0.00030 0.00030 0.00036
Thermal Performance Rating (Category C; Clear Day) BTU per panel per day 24,000 24,000 32,100
Grid dimensions (length x width x depth) in 64.5 x 55 x 4 64.5 x 55 x 4 81 x 55 x 4
Gross surface area ft² 24.54 24.54 30.66
Aperture area ft² 21.68 21.68 27.8
Collector contents gal 0.48 0.48 0.6
Weight lbs 77 77 91
Max. working overpressure psi 150 150 150
Max. stagnation temperature °F 522 522 522
Connection diameter, compression ring mm 15 15 15
Sensor sleeve mm 6 6 6
Glass tube (Ø ext./Ø int./wall thckn./tube lgth.) in 1 7/8 / 1 1/2 / 1/16 / 59 1 7/8 / 1 1/2 / 1/16 / 59 1 7/8 / 1 1/2 / 1/16 / 76
Collector material   AI / Cu / glass / silicone / PBT / EPDM / TE AI / Cu / glass / silicone / PBT / EPDM / TE AI / Cu / glass / silicone / PBT / EPDM / TE
Glass tube material   borosilicate glass 3.3 borosilicate glass 3.3 borosilicate glass 3.3
Selective absorber coating material   aluminum nitride aluminum nitride aluminum nitride
Color (plastic parts)   black black black
Thermal shock test ITW test 06COL513/1 06COL513/1 06COL513/1
Hailstone test according to DIN EN 12975-2 TÜV test 435/142448 435/142448 435/142448
EC type examination   Z-IS-DDK-MUC-07-08-100029919-001 / -003 Z-IS-DDK-MUC-07-08-100029919-001 / -003 Z-IS-DDK-MUC-07-08-100029919-001 / -003
DIN CERTCO registration number   011-7S113R 011-7S113R 011-7S113R
SRCC OG-100 Certification number   2008008D 2008008D 2008008D
High Velocity Wind Certification   pending pending pending
Other tests and approvals   EN 12975, RAL ZU 73, Solar Keymark, ISO 9001 EN 12975, RAL ZU 73, Solar Keymark, ISO 9001 EN 12975, RAL ZU 73, Solar Keymark, ISO 9001

CPC 18 OEM / INOX

Evacuated tube collector with CPC-reflector - 18 evacuated tubes for water, space and process heating, series connection

Scope of Delivery: Fully pre-assembled unit comprising of:

  • Evacuated tubes based on the thermos flask principle
  • Manifold with direct flow heat conduction unit and dry tube connection
  • CPC-reflector

Collectors are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.

Installation Types:

  • On-roof Installation 
  • Flat roof / Wall Installation
  • Ground Installation

Note: The manifold must always be mounted on top. The minimum angle for on-roof and flat roof installation is 15° 

Specification

Series   CPC 18 OEM CPC 18 INOX
Internal piping   copper stainless steel
Color (aluminum frame profile)   aluminum grey slate grey
Surface coating (aluminum frame profile)   anodized powder coated
No. of Evacuated Tubes   18 18
η (based on gross area), according to SRCC % 55.4 55.4
a1 (based on gross area), according to SRCC BTU/hr.ft².°F 0.14300 0.14300
a2 (based on gross area), according to SRCC BTU/hr.ft².°F² 0.00030 0.00030
Thermal Performance Rating (Category C; Clear Day) BTU per panel per day 35,800 35,800
Grid dimensions (length x width x depth) in 64.5 x 82 x 4 64.5 x 82 x 4
Gross surface area ft² 36.70 36.70
Aperture area ft² 32.29 32.29
Collector contents gal 0.63 0.63
Weight lbs 119 119
Max. working overpressure psi 150 150
Max. stagnation temperature °F 522 522
Connection diameter, compression ring mm 15 15
Sensor sleeve mm 6 6
Glass tube (Ø ext./Ø int./wall thckn./tube lgth.) in 1 7/8 / 1 1/2 / 1/16 / 59 1 7/8 / 1 1/2 / 1/16 / 59
Collector material   AI / Cu / glass / silicone / PBT / EPDM / TE AI / Cu / glass / silicone / PBT / EPDM / TE
Glass tube material   borosilicate glass 3.3 borosilicate glass 3.3
Selective absorber coating material   aluminum nitride aluminum nitride
Color (plastic parts)   black black
Thermal shock test ITW test 06COL513/1 06COL513/1
Hailstone test according to DIN EN 12975-2 TÜV test 435/142448 435/142448
EC type examination   Z-IS-DDK-MUC-07-08-100029919-001 / -003 Z-IS-DDK-MUC-07-08-100029919-001 / -003
DIN CERTCO registration number   011-7S113R 011-7S113R
SRCC OG-100 Certification number   2008008C 2008008A
High Velocity Wind Certification   pending pending
Other tests and approvals   EN 12975, RAL ZU 73, Solar Keymark, ISO 9001 EN 12975, RAL ZU 73, Solar Keymark, ISO 9001

OEM 21

Evacuated tube collector - 21 evacuated tubes for water heating, series connection

Scope of Delivery: Fully pre-assembled unit comprising of:

  • Evacuated tubes based on the thermos flask principle
  • Manifold with direct flow heat conduction unit and dry tube connection

Collectors are packed in individual boxes. In addition, there is a sun protection sheet over the evacuated tubes.

Installation Types:

  • On-roof Installation 
  • Flat roof Installation
  • Horizontal Installation
  • Ground Installation

Specification

Series   OEM 21
Internal piping   copper
Color (aluminum frame profile)   aluminum grey
Surface coating (aluminum frame profile)   anodized
No. of Evacuated Tubes   21
η (based on gross area), according to SRCC % 42.4
a1 (based on gross area), according to SRCC BTU/hr.ft².°F 0.20102
a2 (based on gross area), according to SRCC BTU/hr.ft².°F² 0.00061
Thermal Performance Rating (Category C; Clear Day) BTU per panel per day 23,500
Grid dimensions (length x width x depth) in 64.5 x 57 x 4
Gross surface area ft² 25.45
Aperture area ft² 15.3
Collector contents gal 0.7
Weight lbs 118
Max. working overpressure psi 150
Max. stagnation temperature °F 428
Connection diameter, compression ring mm 15
Sensor sleeve mm 6
Glass tube (Ø ext./Ø int./wall thckn./tube lgth.) in 1 7/8 / 1 1/2 / 1/16 / 59
Collector material   AI / Cu / glass / silicone / PBT / EPDM / TE
Glass tube material   borosilicate glass 3.3
Selective absorber coating material   aluminum nitride
Color (plastic parts)   black
Thermal shock test ITW test 07COL517
Hailstone test according to DIN EN 12975-2 TÜV test 435/142448
EC type examination   Z-IS-DDK-MUC-07-08-100029919-003
DIN CERTCO registration number   011-7S114R
SRCC OG-100 Certification number   2008011A
High Velocity Wind Certification   No
Other tests and approvals   EN 12975, RAL ZU 73, Solar Keymark, ISO 9001

Thermosiphones

Linuo Ritter International offers a wide variety of pressurized and non-pressurized thermosiphon systems.
For further information please visit the Linuo Ritter International website.

Specification: Evacuated tubes

Evacuated tubes
Key component of the forced circulation systems (collectors) and thermosiphons

Coating material SS-AL/N/Cu or SS-AL/N/Cu

Scope of delivery Evacuated tubes are packed in boxes.

Specification

Item    
Absorbance rate after coating (AM 1.5) α% ≥94.5
Absorbance rate after evacuating (AM 1.5) α% ≥93.5
Emission rate after coating (80±5°C) α% ≤6
Emission rate after evacuating (80±5°C) α% ≤6.5
Stagnation parameter m²°C/Kw ≥240
Solar radiance exposure Btu/ft² ≤265
Average heat loss coefficient Btu/h.ft².°F ≤0.1234
Selective coating material   SS-AL-N/Cu, SS-AL-N/Cu
Impact resistance   Steel Ball Test: Steel ball with diameter of 1.2" fall on the evacuated tube vertically from 1.5' height.
Vacuum Degree Pa ≤3x10(-3)
Pressure MPa 0.6
Transparent (AM 1.5)   ≥0.89 (ISO9806-1: 1994)

For further information please contact our sales team or download our current product catalogue.